Your water quantity is relatively very low in percentage terms. Then you can enter the mixed fluid properties in place of the shell side fluid.Ĥ. I would suggest another option is to consider using a process simulator like hysys where you can enter respective fluids, conditions and then calculate the properties from that for the mixed fluid. and then enter the calculated combined fluid properties by yourself in htri.īut then you will have to separately account for evaporation of the fluid and evaporation of water and their individual vapour properties which will be a tedious task.ģ. Otherwise you can separately use the standard mixing rules for mixing of the individual properties in proportion of their respective mole fractions / wt fractions depending on whether the specific property is based on moles or weight (Eg. The overall fluid properties will then be inclusive of the water fraction as well, but you will be able to see only the combined fluid properties.Ģ. If you enter the values, you can see the respective specific properties of the overall shell side fluid. the fluid and water as well in the components tab just below grid properties tab. You can enter the individual mole fractions or weight fractions for the Shell side fluid if you know the balance of both the liquid components, by adding both components - ie.